DN10-3200 4-20ma Output Electromagnetic Smart Digital Chemical Water Flow Meter With Flange Electronic Flowmeter
Product introduction:
The explosion-proof electromagnetic flowmeter is composed of electromagnetic flow sensor and converter to measure the volume flow of various conductive fluid or liquid solid diphase medium in the pipeline.
Product features:
1.The measurement of flow is not affected by the density, viscosity, temperature, pressure and conductivity of the fluid, and the sensor induced voltage signal is linearly with the average velocity, so the measurement accuracy is high.
2.Measurement of unimpeded flow in the pipeline without additional pressure loss;The sensor has a very long life.
3.Since the induction voltage signal is formed in the middle of the whole magnetic field, it is the average of the pipeline's load, so the straight tube required for the sensor is shorter and the length is five times the diameter of the pipe.
4.Various electrodes and lining materials can meet the requirements of corrosion resistance and wear resistance.
5.HXLDE converter adopts the most advanced international latest MCU and surface-mount technology, reliable performance, high precision, low power consumption, zero point stability, easy parameters setting, click on the Chinese display, LCD display, cumulative flow instantaneous flow rate and flow velocity, flow percentage, etc.
6.The two-way measurement system can measure forward flow and reverse flow, adopt special production process and high quality materials to ensure that the product's performance is stable for a long time.
Technical indicators: Nominal diameter DN (mm)
Dn10-3200, insert mode DN200
Flow direction: positive, negative, net flow
Accuracy: tube type: 0.2, 0.5, 1.0 (according to the caliber) insert type: 2.5
Low temperature measured medium: rubber lining: - 20 ℃ ~ + 90 ℃
Ptfe lining: - 30 ℃ ~ 150 ℃
Rated working pressure:
Pipe line: dn10-dn50: no more than 4.0mpa dn65-dn250: no more than 1.6mpa dn300-1000: less than or less than 1.0mpa
Insert:>80 0.25-25MPa
Flow measurement range: flow measurement range of 0.5 ~ 10m/s
Tube type: 0.5 ~ 10m/s, recommended 1 ~ 5m/s
Insert type: 0.5 ~ 10m/s
Low temperature: - 25 ℃ ~ + 60 ℃
Communication interface: RS232, RS485, HART
The conductivity range: the conductivity of the measured flow body is greater than that of 5 mu s/cm. Most of the medium with water is the electric conductivity of 200 ~ 800 mu s/cm, and the electromagnetic flowmeter can be used
Electrode materials: stainless steel, titanium, tantalum, HHS alloy, platinum-iridium alloy or other special electrode materials
Protection class: diving: IP68, other type IP65
Power supply: AC220V 50HZ, DC24V
Direct tube length: pipeline type: upstream is greater than 5D, downstream is greater than 2D
Connection mode: pipe type: gb9119-2000 standard flanges
Insert type: thread connection, ball valve specification: DN50
Low explosion-proof marks: Exdia (ia) Ga Ⅱ CT6 Gb
Relative humidity: 5% ~ 95% RH
Electrical interface: M20 x 1.5 threads
Any DN Can Be Customized
Company Information
Application:
The explosion-proof electromagnetic flowmeter is mainly used to measure the volume flow of the conductive liquid and slurry in the closed pipe.Such as water, sewage, slurry, pulp, all kinds of acid, alkali, salt solution, food slurry, etc., widely used in petroleum, chemical, metallurgical, textile, food, pharmaceutical, paper making industries and environmental protection, municipal administration, water conservancy construction and other fields.
FAQ
1:May i know your MOQ? How long it takes for make a sample?
MOQ:5 PCS, Normally takes 5 working days for produce a sample
2: How do you transport the goods?
We transport the goods by container. Our factory possesses long-term cooperation with ship agency which can provide you lowest shipping fee
3:Can you satisfy my special requirement?
Definitely! We are direct manufacturer and we have strong producing capacity and R&D capacity!
4: Delivery time
Depend on the type of goods and the QTY and the shipping date,usually the goods can be ok on around 20 working days.
5: After-sales warranty
We provide 18 months warranty period under your correct using after customers' purchasing.
Electromagnetic flowmeter flow range table
DN mm Flow range m3/h DNmm Flow rangem3/h
φ15 0.06~6.36 φ450 57.23~5722.65
φ20 0.11~11.3 φ500 70.65~7065.00
φ25 0.18~17.66 φ600 101.74~10173.6
φ40 0.45~45.22 φ700 138.47~13847.4
φ50 0.71~70.65 φ800 180.86~18086.4
φ65 1.19~119.4 φ900 228.91~22890.6
φ80 1.81~180.86 φ1000 406.94~40694.4
φ100 2.83~282.60 φ1200 553.90~55389.6
φ150 6.36~635.85 φ1600 723.46~72345.6
φ200 11.3~1130.4 φ1800 915.62~91562.4
φ250 17.66~176.25. φ2000 1130.4~113040.00
φ300 25.43~2543.40 φ2200 1367.78~136778.4
φ350 34.62~3461.85 φ2400 1627.78~162777.6
φ400 45.22~4521.6 φ2600 1910.38~191037.6